[35195] in Hotline Meeting
Palladium up and running.
daemon@ATHENA.MIT.EDU (ndpope@MIT.EDU)
Wed Oct 9 10:03:07 1996
From: ndpope@MIT.EDU
To: hotline@MIT.EDU
Cc: pcservice@MIT.EDU, ccount@MIT.EDU
Date: Wed, 09 Oct 1996 10:02:42 EDT
Palladium was reported as being down on Monday afternoon. I went by Tuesday
morning and replaced the power supply which allowed it to power up, but we still had
an ecc/parity error. I went by this morning (just moments ago) and replaced the logic
board. It's up and running now and I'm sending this from palladium.
Machine name: Palladium
Machine s/n: 0800690AD930
Machine type: R5000
Machine Tag: MIT-0305000
Location : 13-5051
Parts used: Power Supply (060-0008-001) and Logic board (030-8123-016)
Log #: R8761
Status: Closed
Kyle Pope
ndpope@mit.edu
MIT PC Service
pcservice@mit.edu
------- Forwarded Message
Received: from PACIFIC-CARRIER-ANNEX.MIT.EDU by po10.MIT.EDU (5.61/4.7) id AA11395; Wed, 9 Oct 96 07:07:57 EDT
Received: from HECTOR.MIT.EDU by MIT.EDU with SMTP
id AA26755; Wed, 9 Oct 96 07:07:51 EDT
From: jjmorey@MIT.EDU
Received: by hector.MIT.EDU (5.57/4.7) id AA21980; Wed, 9 Oct 96 07:07:49 -0400
Date: Wed, 9 Oct 96 07:07:49 -0400
Message-Id: <9610091107.AA21980@hector.MIT.EDU>
To: pcservice@MIT.EDU
/***** hector:hotline / priam!jjmorey / 7:07 am Oct 9, 1996*/
/***** hector:hotline / priam!ccount / 8:23 pm Oct 8, 1996*/
From ccount@MIT.EDU Tue Oct 8 20:23:28 1996
To: hotline@MIT.EDU
Cc: ccount@MIT.EDU
Reply-To: ccount@MIT.EDU
Subject: palladium
Date: Tue, 08 Oct 1996 20:23:25 EDT
From: "Dr. Craig A. Counterman" <ccount@MIT.EDU>
Have you tried to fix this yet?
When I reported the problem yesterday, it was off and stayed off.
Today, it's got power, but panics and fails to come up with ECC/Parity error.
Craig
/* ---------- */
RE:Palladium
Im forwarding this to pcservice.
10/9
7am
JJ
/* ---------- */
------- End of Forwarded Message