[4744] in linux-scsi channel archive

home help back first fref pref prev next nref lref last post

Re: Another one [disk] bites the dust...

daemon@ATHENA.MIT.EDU (Marc SCHAEFER)
Mon Sep 28 03:21:55 1998

Date: 	Mon, 28 Sep 1998 08:19:27 +0200 (MEST)
From: Marc SCHAEFER <schaefer@alphanet.ch>
To: Brendan Miller <brmiller@wco.com>
Cc: linux-scsi@vger.rutgers.edu
In-Reply-To: <19980927124405.17217@xenon.kudzu.gammalink.com>



On Sun, 27 Sep 1998, Brendan Miller wrote:

> On Sat, Sep 26, 1998 at 10:44:47PM +0200, Marc SCHAEFER wrote:
> > Brendan Miller <brmiller@xenon.kudzu.gammalink.com> wrote:
> > > Sep 20 17:39:20 xenon kernel: SCSI disk error : host 0 channel 0 id 1 lun 0 return code = 28000002
> > > Sep 20 17:39:20 xenon kernel: extra data not valid Current error sd08:11: sense key Not Ready
> > > Sep 20 17:39:20 xenon kernel: Additional sense indicates Logical unit is in process of becoming ready
> > 
> > Someone has switched off the power to that drive, and on again. Maybe
> > your power supply is too small and two drives seeking at the same
> > time took too much power.
> 
> Well, to end this saga, I sent the disk back to the manufacturer and got
> a new one.  The new one works just fine.  I suspect the old one just 
> went "lame".  As for the power consumption, this disk along with two
> others and a CDROM are in an external enclosure with a 200W power supply.
> I don't think it was the power.

Thinking again I would have expected a 6 29 00 sense first (SCSI RESET
OR POWER ON OCCURED) if it was power.


-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@vger.rutgers.edu

home help back first fref pref prev next nref lref last post