[917] in testers
vax 7.1A: xcluster gives bogus data on Vax (but not RT)
daemon@ATHENA.MIT.EDU (daemon@ATHENA.MIT.EDU)
Tue Jul 24 14:49:50 1990
To: testers@ATHENA.MIT.EDU
Date: Tue, 24 Jul 90 14:49:25 EDT
From: Ezra Peisach <epeisach@ATHENA.MIT.EDU>
System name: medusa
Type and version: CVAXSTAR 7.1A (1 update(s) to same version)
Display type: SM
What were you trying to do?
To run the program
What's wrong:
1) Both vax and rt gives 0's for everything
2) On the vax, selecting m1-142, gives really bogus numbers
(large negative quantities) while on an RT it's all zero's
What should have happened:
1) The server should be giving real data
2) The bogus negative stuff should be fixed.
Please describe any relevant documentation references:
xcluster(1)