[917] in testers

home help back first fref pref prev next nref lref last post

vax 7.1A: xcluster gives bogus data on Vax (but not RT)

daemon@ATHENA.MIT.EDU (daemon@ATHENA.MIT.EDU)
Tue Jul 24 14:49:50 1990

To: testers@ATHENA.MIT.EDU
Date: Tue, 24 Jul 90 14:49:25 EDT
From: Ezra Peisach <epeisach@ATHENA.MIT.EDU>

System name:		medusa
Type and version:	CVAXSTAR 7.1A (1 update(s) to same version)
Display type:		SM

What were you trying to do?
	To run the program

What's wrong:
	1) Both vax and rt gives 0's for everything
	2) On the vax, selecting m1-142, gives really bogus numbers
	(large negative quantities) while on an RT it's all zero's

What should have happened:
	1) The server should be giving real data
	2) The bogus negative stuff should be fixed.


Please describe any relevant documentation references:
	xcluster(1)

home help back first fref pref prev next nref lref last post