[870] in Athena Bugs

home help back first fref pref prev next nref lref last post

Re: W20-575-4 RTPC

daemon@ATHENA.MIT.EDU (Ken Raeburn)
Fri Sep 9 11:53:31 1988

Date: Fri, 9 Sep 88 11:52:35 EDT
From: Ken Raeburn <raeburn@ATHENA.MIT.EDU>
To: Brian W. Melanson <bwmelans@ATHENA.MIT.EDU>
Cc: kubitron@ATHENA.MIT.EDU, mckie@ATHENA.MIT.EDU
Cc: hotline@ATHENA.MIT.EDU, cc@ATHENA.MIT.EDU, bugs@ATHENA.MIT.EDU
In-Reply-To: Brian W. Melanson's message of Fri, 9 Sep 88 11:34:28 EDT,

   From: <bwmelans@ATHENA.MIT.EDU>
   Date: Fri, 9 Sep 88 11:34:28 EDT


   #4 when powered up hangs on DEBUG> with the following errors:

	level 2 intr.: IAR = 1000d6 ICS=87 <CHKSTOP-MASK> cs=10 001000D6 
		CDZEC48 r2-#B74(r14)

   then reason why I sent this bugs is because field service doesn't know how 
   to use this, DEBUG>, and I don't know how to use it. The actual hardware has
   been fixed but this error cannot be cleared. Any and all help would be great.
   So I can relay the solution to this problem to field service.

   thanks for your time

   Brian (cluster patrol)9/9/1988


Brian:

The "DEBUG>" mode you should be able to get out of with the normal key
sequence for rebooting, ctrl-alt-pause.  The "level 2 intr" message is
one I'm not familiar with, and may indicate some other problem if you
can't get out of it by rebooting or power-cycling or maybe even
reloading.  (I would suspect hardware if everything including
reloading doesn't help.  Unfortunately, I don't know enough low-level
stuff about the RTs to really be able to say.  John Kubiatowicz or Bob
McKie may be able to help.)

-- Ken

home help back first fref pref prev next nref lref last post