[9794] in Hotline Meeting

home help back first fref pref prev next nref lref last post

w20-575-42 memory errors

daemon@ATHENA.MIT.EDU (epeisach@Athena.MIT.EDU)
Mon Jul 20 10:14:38 1992

From: epeisach@Athena.MIT.EDU
Date: Mon, 20 Jul 92 10:14:26 -0400
To: hotline@Athena.MIT.EDU


The machine received a parity memory error.... While uerf listed it as a
soft error, it caused the machine to panic. Perhaps the memory should be
checked out...

********************************* ENTRY     3. *********************************

----- EVENT INFORMATION -----

EVENT CLASS                             ERROR EVENT
OS EVENT TYPE                  101.     MEMORY ERROR
SEQUENCE NUMBER                 22.
OPERATING SYSTEM                        ULTRIX 32
OCCURRED/LOGGED ON                      Sun Jul 19 06:32:27 1992 EDT
OCCURRED ON SYSTEM                      w20-575-42
SYSTEM ID                 x82070230     HW REV: x30
                                        FW REV: x2
                                        CPU TYPE: R2000A/R3000
PROCESSOR TYPE                          KN02-CA

----- UNIT INFORMATION -----

UNIT CLASS                              MEMORY
UNIT TYPE                               KN02CA MEMORY
ERROR SYNDROME                          MEMORY PARITY ERROR

----- KN02CA MEMORY REGISTERS -----

MEM REG                   x18000100     HARD CNT 0.
                                        SOFT CNT 1.
                                        TRAN CNT 0.
                                        DATA BIT IN ERROR
                                        LOW BYTE IN ERROR
                                        MEMORY PARITY ERROR: SOFT
                                        D16-31 ON BANK # x0
PHYSICAL ADDR             x00D26BE0
EPC                       x00445BE0
BAD VIRT ADR              x00445BE0
MSR                       x00142400
                                        16MBYTE BANKS
                                        LAST BANK =  x2
                                        MABEN ENABLED
                                        INTERRUPT PERIOD =  1MS

----- ADDITIONAL INFO -----

CONTROLLER NO.                   1.
ERRS ON THIS ADDR                1.
********************************* ENTRY     4. *********************************

----- EVENT INFORMATION -----

EVENT CLASS                             ERROR EVENT
OS EVENT TYPE                  200.     PANIC
SEQUENCE NUMBER                 23.
OPERATING SYSTEM                        ULTRIX 32
OCCURRED/LOGGED ON                      Sun Jul 19 06:32:27 1992 EDT
OCCURRED ON SYSTEM                      w20-575-42
SYSTEM ID                 x82070230     HW REV: x30
                                        FW REV: x2
                                        CPU TYPE: R2000A/R3000
PROCESSOR TYPE                          KN02-CA
PANIC MESSAGE                           memory parity error in shared page
KERNEL STACK
INTERRUPT STACK