[7461] in Hotline Meeting
hodge crash/disk errors (again)
daemon@ATHENA.MIT.EDU (Calvin Clark)
Sat Jan 18 10:00:03 1992
Date: Sat, 18 Jan 92 09:58:45 -0500
From: Calvin Clark <ckclark@mit.edu>
To: hotline@Athena.MIT.EDU
Cc: sipb-staff@Athena.MIT.EDU
Reply-To: ckclark@mit.edu
HODGE panicked on me. It did not come up at first (got stuck in test 0
7..6..5..4..3..2..1..<wait forever>) I managed to get it to come up,
but it was not pretty.
The following soft error may be relevant (the actual crash at ~9 AM had
no errors logged)
********************************* ENTRY 1. *********************************
----- EVENT INFORMATION -----
EVENT CLASS ERROR EVENT
OS EVENT TYPE 102. DISK ERROR
SEQUENCE NUMBER 13.
OPERATING SYSTEM ULTRIX 32
OCCURRED/LOGGED ON Sat Jan 18 03:12:44 1992 EST
OCCURRED ON SYSTEM hodge
SYSTEM ID x82011601 HW REV: x1
FW REV: x16
CPU TYPE: R2000A/R3000
PROCESSOR TYPE KN01
----- UNIT INFORMATION -----
UNIT CLASS SCSI DISK
UNIT TYPE RZ23
CONTROLLER NO. 0.
UNIT NO. 3.
----- SCSI INFORMATION -----
REVISION 2.
ERROR TYPE x0000 DEVICE ERROR
SUB-ERROR TYPE 0.
SCSI ID 3.
FLAGS x00220019 SCSI CMD PKT
SCSI EXTENDED SENSE
SCSI CTLR & DMA REGS
SOFT ERROR
DECSII
CMD BLK x000000000000001080FF0208
CMD x0008 READ