[44609] in Hotline Meeting
LOG # 118414 Rep.Form Wimsey
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Fri Aug 21 17:11:33 1998
To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU
Date: Fri, 21 Aug 1998 17:11:27 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 8/24/98
------------
DHL# 8794366641
---------------------
RMA# 342412
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: 535 hard drive for a Sparc5 (70mhz)
------------------------------------------------
Part Number: 370-1844-03
------------------------------
Hotline Number: 118414
---------------------------
Building and Room#: N42 (basement)
-----------------------
Machine Type: Sparc5 (70mhz)
-----------------------------
CPU S/N: 446F3082
----------------------------------
Hostname: Wimsey
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Media errors & can not read certain blocks.
------------------------------------------------------
Diags Used:
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the hard drive under sun self maint.
------------------------------------------------------
Comments: Have re-installed the software, and the system is now back up
------------------------------------------------------
and operating properly.
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 8//21/98
------------