[42562] in Hotline Meeting
REPAIR FORM SGI-02 (CSA system)
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Tue Mar 24 18:25:14 1998
To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Tue, 24 Mar 1998 18:25:09 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Silicon Graphics Inc.
1 Amherst St 981 Almanor Ave
Mail Stop E40-362 Sunnyvale CA. 94086-0000
Cambridge, Ma 02139
(617) 253-1410
(TO PLACE HARDWARE SERVICE CALLS)
***** 1-800-800-4744 *****
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped:
------------
FedEx #
---------------------
Case ID # 0927903
---------------------
******************************************************************
Part Description: 4 gig hard drive for an SGI 02
------------------------------------------------
Part Number: 013-1579-001
------------------------------
Hotline Number: 3314
---------------------------
Building and Room#: E40-014B
-----------------------
Machine Type: sgi 02
-----------------------------
CPU S/N: 08006902E2BA
----------------------------------
Hostname: sgi-02
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Physical address memory errors in slot 1 & 2. Hard drive also
------------------------------------------------------
Diags Used: noticed as surging. Many Dimm swaps/system bd swaps & hard
------------------------------------------------------
drive swaps took place trying to find out why the memory
------------------------------------------------------
Resolution: was failing.
------------------------------------------------------
Comments: The hard drive was swapped, software installed, and the system
------------------------------------------------------
is now up and operating properly.
------------------------------------------------------
Repaired By: L.A.I. & Joe
------------------
Date: 3/24/98
------------