[42561] in Hotline Meeting

home help back first fref pref prev next nref lref last post

CSA System (SGI-02)

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Tue Mar 24 18:17:33 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU
Date: Tue, 24 Mar 1998 18:17:28 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

This system was found with Physical address memory errors in slot 2. Once 
moving the Dimm to slot 1, the same error happened. What appeared to be 
happening, was not really happening. I will explain. My self & joe had did
extensive troubleshooting on this failure. Only having 1 CSA 02, we had to 
interact with one from stock. The hard drive in the CSA 02 system started 
surging on spin up etc... I believe that the hard drive was the culprit of
this particular/peculiar failure. One was led to believe that the memory
Dimms were bad, (according to the errors). Howver, I have concluded that the 
failing hard drive had, somehow caused the indirect memory Dimm errors. Based
on this troubleshooting, the hard drive, from the stock room 02 is now in the 
CSA 02, which is now currently up and running with no problems.
Have called SGI for the hard drive replacement.

Title # (3314)
SysName: SGI-02 (CSA system)
S/N    : 08006902E2BA
Location: E40-014B
CASE #  : 0927903
                          --Lou  3/24/98