REPAIR FORM M1-142-12 SS4 Freeze Caper:

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon Feb 9 19:25:58 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Mon, 09 Feb 1998 19:25:53 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
1 Amherst St                            257 Cederhill St
Mail Stop E40-334                       Marlboro, Ma 01752
Cambridge, Ma 02139                     1 800 626 1661
Customer Number = 100116                1 508 460 1800

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   2/10/98
              ------------
DHL#   8500543122
     ---------------------
RMA#   314601
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   150 watt power supply & a 110mhz sys.bd. for a Sparc4
                  ------------------------------------------------
Part Number:   300-1279-02 & 501-3134
             ------------------------------
Hotline Number:   2063
                ---------------------------
Building and Room#:   1-142
                    -----------------------
Machine Type:   Sparc4
              -----------------------------
CPU S/N:   628F0AC0
         ----------------------------------
Hostname:   M1-142-12
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     Many LE0 errors & is hub link connected msg's. System running
            ------------------------------------------------------
Diags Used:   very slow. System sometimes hangs as well. Running Solaris 2.5.1
            ------------------------------------------------------
              with Athena 8.1. Have changed the 50 watt pwr supply to the 150
            ------------------------------------------------------
Resolution:   watt one, and have replaced the 110mhz system bd.
            ------------------------------------------------------
Comments:     System now back up minus the LE0 Hub Link Msg's. its possible
            ------------------------------------------------------
              that the 50 watt pwr supply may have caused the bd to fail.
            ------------------------------------------------------
Repaired By:   Please see Sun FCO on pwr supply issue.
             ------------------
Date:  L.A.I.  2/9/98
      ------------