REPAIR FORM M1-142-13 SS$ Freeze Caper:

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Thu Nov 13 17:36:16 1997

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Thu, 13 Nov 1997 17:35:59 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
1 Amherst St                            257 Cederhill St
Mail Stop E40-334                       Marlboro, Ma 01752
Cambridge, Ma 02139                     1 800 626 1661
Customer Number = 100116                1 508 460 1800

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   
              ------------
DHL#   Using Polaris form for Sun time/materials.
     ---------------------
RMA#   Unavailable at this time
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   150 watt power supply for a SS4
                  ------------------------------------------------
Part Number:   300-1279-02
             ------------------------------
Hotline Number:   B179
                ---------------------------
Building and Room#:   1-142
                    -----------------------
Machine Type:   Sparc4
              -----------------------------
CPU S/N:   628F0AE9
         ----------------------------------
Hostname:   M1-142-13
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     A few days after receiving a 1REV50 system bd, followed by a 
            ------------------------------------------------------
Diags Used:   faulty 32 meg simm, the system went back to freezing/hanging.
            ------------------------------------------------------
              Furthur troubleshooting showed that the 50 watt power supply
            ------------------------------------------------------
Resolution:   needed to be replaced with the newer 150 watt power supply.
            ------------------------------------------------------
Comments:     This, and a software reload has corrected this problem. System
            ------------------------------------------------------
              now back up and in use at this point in time.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  11/13/97
      ------------