Repair Form W20-575-104

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Fri Oct 10 14:22:09 1997

To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU
Date: Fri, 10 Oct 1997 14:22:04 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                    Silicon Graphics Inc.
1 Amherst St                           981  Almanor Ave
Mail Stop E40-362                      Sunnyvale   CA.  94086-0000
Cambridge, Ma 02139                     
(617) 253-1410 
                                       (TO PLACE HARDWARE SERVICE CALLS)
                                 
                                        *****   1-800-800-4744   *****
 
                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   
              ------------
FedEx #  
          ---------------------
Case ID #  0847472
          ---------------------
 
******************************************************************
Part Description: XZ bds for an indy 46xz  
                  ------------------------------------------------
Part Number:   030-8234-002 PCA GR4  & 030-8235-002 PCA VB3
             ------------------------------
Hotline Number:   A028
                ---------------------------
Building and Room#:   W20-575
                    -----------------------
Machine Type:   indy 46xz
              -----------------------------
CPU S/N:   0800690891CA
         ----------------------------------
Hostname:   W20-575-104
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     CRT displaying red 'X' & dark blue square perimeter around crt
            ------------------------------------------------------
Diags Used:   Software loaded several times, xz bds replaced, which fixed
            ------------------------------------------------------
              system for about 30 minutes. System currently still down.
            ------------------------------------------------------
Resolution:   XZ bds have been replaced, but may have been defective.
            ------------------------------------------------------
Comments:     Right now there is no current CSA 46xz to be used for trouble
            ------------------------------------------------------
              shooting furthur.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  10/10/97
      ------------