REPAIR FORM SGI Stage2

daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Fri Apr 18 13:36:59 1997

From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Cc: jjmorey@MIT.EDU, larugsi@MIT.EDU
Date: Fri, 18 Apr 1997 13:36:55 EDT

MIT                                    Silicon Graphics Inc.
1 Amherst St                           981  Almanor Ave
Mail Stop E40-362                      Sunnyvale   CA.  94086-0000
Cambridge, Ma 02139                     
(617) 253-1410 
                                       (TO PLACE HARDWARE SERVICE CALLS)
                                 
                                        *****   1-800-800-4744   *****
 
                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   
              ------------
FedEx #  
          ---------------------
Case ID # 0761603
          ---------------------
 
******************************************************************
Part Description:  Scsi cable for an SGI Indy    
                  ------------------------------------------------
Part Number:   018-8115-001  REV EJ
             ------------------------------
Hotline Number:   4253
                ---------------------------
Building and Room#:   E40-014B
                    -----------------------
Machine Type:   sgi indy 50xl
              -----------------------------
CPU S/N:   0800690AD930
         ----------------------------------
Hostname:   Stage2
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     Sgi system would not come up and failed diagnostics.
            ------------------------------------------------------
Diags Used:   Reseated all hardware components. No go. Traced failure to the 
            ------------------------------------------------------
              scsi cable.
            ------------------------------------------------------
Resolution:   Have replaced the cable under sgi self maint.
            ------------------------------------------------------
Comments:     
            ------------------------------------------------------
              
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  4/17/97
      ------------