[36290] in Hotline Meeting
REPAIR FORM M11-116-7
daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Mon Dec 23 13:24:55 1996
From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Cc: joewelch@MIT.EDU, larugsi@MIT.EDU
Date: Mon, 23 Dec 1996 13:24:50 EST
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 12/23/96
------------
DHL# 8210243926
---------------------
RMA# 259379
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: Sparc4 floppy drive (new style)
------------------------------------------------
Part Number: 540-2854-01
------------------------------
Hotline Number: C221
---------------------------
Building and Room#: 11-116
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 630F01F9
----------------------------------
Hostname: M11-116-7
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Drive receiving read errors, and sometimes not seen by system
------------------------------------------------------
Diags Used:
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced drive under sun self maint.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 12/20/96
------------