[20556] in Hotline Meeting

home help back first fref pref prev next nref lref last post

12-124 RS6000/220 Luther

daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Tue Jan 11 22:34:38 1994

From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Cc: burke@MIT.EDU, ljr@MIT.EDU
Date: Tue, 11 Jan 94 22:34:20 EST

I have investigated this system, that was reported with no image on the 
monitor. I have received a shock, disconnecting the power cord from the A.C.
outlet. I am o.k. and have shaken it off. Furthur investigation showed that
once I moved the monitor, running water started to flow out. After 
investigating furthur, it was discovered that the overhead windows were left
open during the past snow storm, and now looks like the monitor has shorted
out. Water stains are present all over the cpu as well. I have contacted 
Jerry, and it was decided that a service call will be placed to IBM, and that
we will get billed, and will bill a person by the name of Ruben who is in 
charge of this area.
Location: 12-124
Sys.Name Luther
IBM RS6000/220  cpu S/N  7011-26-16059
Monitor: 8517   S/N      23-1004505 
Contact: Ruben X3-5011
Title # (
LOG # SVRYR
Have forwarded to Cynthia.
** Note that the person at this cluster area (12-124) refused to give out the
code to this area. So, I have given IBM the instructions to contact JJ or
JC via 1410 to try and make the arrangements to access 12-124.
                       --Lou  1/11/94