[84521] in North American Network Operators' Group
Re: CAT5 surge/lightning strike protection recommendations?
daemon@ATHENA.MIT.EDU (Bryan Fields)
Wed Sep 14 13:04:19 2005
From: Bryan Fields <Bryan@illiana.net>
To: nanog@merit.edu
In-Reply-To: <20050913202451.GB40445@mighty.grot.org>
Date: Wed, 14 Sep 2005 12:02:38 -0500
Errors-To: owner-nanog@merit.edu
On Tuesday 13 September 2005 03:24 pm, R.P. Aditya wrote:
> Anyone have recommendations (tested/practical is best :-)?
First bond the cable shield to earth at the entry point in both buildings.
Second use a Tripplite DNET-1 at both buildings. make sure you have a single
point ground terminal that everything it bonded to and then that is grounded.
I am in the chicago area, and have towers and locations that have ethernet
cables running up to radios. We use this meathod, and don't have problems.
Worst we had after last night's T-storm was a site with out power :-)
--
Bryan Fields
Chief RF Engineer/Partner
illiana.net
219-306-1805