[190372] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Brocade Fabric Help

daemon@ATHENA.MIT.EDU (Fred Hollis)
Thu Jun 30 17:55:50 2016

X-Original-To: nanog@nanog.org
To: nanog@nanog.org, nanog@ics-il.net
From: Fred Hollis <fred@web2objects.com>
Date: Thu, 30 Jun 2016 23:55:46 +0200
In-Reply-To: <1217501659.6466.1467315681031.JavaMail.mhammett@ThunderFuck>
Errors-To: nanog-bounces@nanog.org

Hello Mike,

Running a few larger Brocade VDX fabrics here...

In case of that message, there is no other option not to reset that 
specific new switch and then re-join the device. I had that a few times, 
too.

It happens when you already did some configuration changes on the new 
switch and the older fabric members weren't aware of that.

On 30.06.2016 at 21:41 Mike Hammett wrote:
> I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea.
>
> One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
> The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
>
> I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve that.
>
>
> VDX-6720s running 4.1.3b.
>
>
>
>
> -----
> Mike Hammett
> Intelligent Computing Solutions
> http://www.ics-il.com
>
>
>
> Midwest Internet Exchange
> http://www.midwest-ix.com
>
>