I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea. 

One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) 
The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) 

I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve that. 