[123289] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Alcatel-Lucent

daemon@ATHENA.MIT.EDU (Scott Weeks)
Thu Mar 4 18:56:37 2010

Date: Thu, 4 Mar 2010 15:54:52 -0800
From: "Scott Weeks" <surfer@mauigateway.com>
To: <nanog@nanog.org>
Reply-To: surfer@mauigateway.com
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org



--- mirotrem@gmail.com wrote:
I'll have to second everything everyone is saying.  Absolutely pleased
with everything about them.  Just wish I had more 7750s instead of
7450s.
----------------------------------------------


That reminds me of one thing that adds more complexity.  We carry our internet in a VPRN for various reasons.  The 7450s don't do BGP AFAIK in a VPRN.  So, if your downstream BGP customers will physically attach to the 7450 you'll have to epipe over to a 7750 to terminate BGP.  Then, since the epipe doesn't go down, you'll have to do BFD with the customer.  Many customers say "do what?"...  ;-)  If you don't do BFD they'll have to wait for the BGP session to time out.

scott


home help back first fref pref prev next nref lref last post