gv (Gaussview) problem on Athena 10 cluster machine

daemon@ATHENA.MIT.EDU (Alex T Prengel)
Wed Feb 18 17:58:01 2009

Message-Id: <200902182256.n1IMuu5e014087@outgoing.mit.edu>
To: testers@MIT.EDU
cc: alexp@MIT.EDU, athena10@MIT.EDU
Date: Wed, 18 Feb 2009 17:56:50 -0500
From: Alex T Prengel <alexp@MIT.EDU>


Another one- in running gv on a 745 cluster machine with:

	setup gaussian
	gv &

in the xterm that opens, windows don't refresh properly when the application's
windows open. The launch terminal prints:


*********************************WARN_ONCE*********************************
File r300_render.c function r300Fallback line 371
Software fallback:ctx->RenderMode != GL_RENDER
***************************************************************************

Again, I don't see this on a 755 workstation install at Hardy. The application
uses OpenGL- radeon graphics driver issue perhaps?

                                         Alex