[7476] in Athena Bugs

home help back first fref pref prev next nref lref last post

rt 7.2R: xess

daemon@ATHENA.MIT.EDU (smyser@ATHENA.MIT.EDU)
Fri Apr 26 12:12:55 1991

From: smyser@ATHENA.MIT.EDU
To: bugs@ATHENA.MIT.EDU
Date: Fri, 26 Apr 91 12:12:41 EDT

System name:		gis
Type and version:	RTPC-ROMPC 7.2R
Display type:		megapel

What were you trying to do?
   Using the vaxstation 3100 'klimt', I was running Xess and sending the 
   display to another workstation.  This has happened on several kinds of
   machines at different times.  I was trying to fill in the motif dialog
   box text widgets for things like X range, Y range and Z range.  Other
   dialog boxes are also affected, like Label text for any axes or for the
   chart title, and the last one it happened to was the filename box in 
   FileSave dialog box.   

What's wrong:
   In all cases I was unable to get characters to be typed into the little
   boxes.  The mouse was able to put the text pointer into the box, and
   by using the mouse to select cells and ranges I was able to get them
   entered in the box, but the KEYBOARD was never directed into the box.
   It's almost like the keyboard focus was being sent to the wrong place.
   It didn't happen immediately, but after a while, and then it stayed
   broken.

What should have happened:
   The characters I typed should have gone into the text widget; instead
   they seemed either to be passed back to the main application window or
   they were just lost entirely.

Please describe any relevant documentation references:
	[Please replace this line with your information.]




home help back first fref pref prev next nref lref last post