Re: Athena 10 crash: dm-2 I/O errors during sustained high-volume

daemon@ATHENA.MIT.EDU (Matthew Belmonte)
Sat Jul 25 23:33:09 2009

Date: Sat, 25 Jul 2009 23:32:58 -0400 (EDT)
Message-Id: <200907260332.n6Q3Ww6Q028793@contents-vnder-pressvre.mit.edu>
From: belmonte@mit.edu (Matthew Belmonte)
To: broder@mit.edu (Evan Broder)
X-Spam-Flag: NO
X-Spam-Score: 0.00
Cc: bugs@mit.edu
Errors-To: bugs-bounces@mit.edu

At 10.55:15 PDT Saturday 25 July, broder wrote,

>My inclination is to blame that sort of error on imminent hard drive failure.

>Can you or somebody else in SIPB try checking SMART information on the
>drive and other stuff like that?


SMART reports no uncorrectable errors, and extended self-test passed.
Also, no further I/O errors reported in /var/log/messages since the ones
at the time of the crash this morning.  (Maybe the disc shits itself only
during extended intervals of high load?)


Script started on Sat 25 Jul 2009 07:05:25 PM EDT
root@opus:/tmp# smartctl -d ata -a /dev/sda
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.10 family
Device Model:     ST3250310AS
Serial Number:    6RY9DYYC
Firmware Version: 3.ADA
User Capacity:    250,000,000,000 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Sat Jul 25 19:10:23 2009 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever
					been run.
Total time to complete Offline
data collection: 		 ( 430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  64) minutes.
SCT capabilities: 	       (0x8035)	SCT Status supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   119   099   006    Pre-fail  Always       -       211382697
  3 Spin_Up_Time            0x0003   098   097   070    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       113
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   077   060   030    Pre-fail  Always       -       57465548
  9 Power_On_Hours          0x0032   091   091   000    Old_age   Always       -       8229
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       112
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   061   055   045    Old_age   Always       -       39 (Lifetime Min/Max 36/39)
194 Temperature_Celsius     0x0022   039   045   000    Old_age   Always       -       39 (0 22 0 0)
195 Hardware_ECC_Recovered  0x001a   072   055   000    Old_age   Always       -       182937103
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@opus:/tmp# smartctl -d ata -t long /dev/sda
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Extended self-test routine immediately in off-line mode".
Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 64 minutes for test to complete.
Test will complete after Sat Jul 25 20:19:15 2009

Use smartctl -X to abort test.

root@opus:/tmp# smartctl -l selftest /dev/sda
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      8232         -
# 2  Short offline       Completed without error       00%         0         -

home help back first fref pref prev next nref lref last post