[9825] in Hotline Meeting
W20-575 Test 5000/25
daemon@ATHENA.MIT.EDU (larugsi@Athena.MIT.EDU)
Wed Jul 22 21:46:09 1992
From: larugsi@Athena.MIT.EDU
To: hotline@Athena.MIT.EDU
Cc: burke@Athena.MIT.EDU
Date: Wed, 22 Jul 92 21:45:52 EDT
This Maxine was reported with no image on the color monitor. I have power
cycled the cpu, and the monitor has come back to life. However, I have a
suspicion that a faulty power supply may be causing this to happen. I have
placed a service call for Thursday.
S/N AB225025AE
PM30-EA
LOG # B76260
--Lou