[7768] in Hotline Meeting
arilinn hw problems (again)
daemon@ATHENA.MIT.EDU (lwvanels@Athena.MIT.EDU)
Thu Feb 13 14:26:42 1992
From: lwvanels@Athena.MIT.EDU
Date: Thu, 13 Feb 92 14:26:03 -0500
To: hotline@Athena.MIT.EDU
Cc: op@Athena.MIT.EDU
Reply-To: lwvanels@mit.edu
Arilinn, the RT in W20 slated to be the third zephyr server, was down again
today with LED "88"; this is the second time this had happened in the past
week.
Running diags on it showed a problem with the system unit (SR #13-403),
which by my reading of the manual shows a problem in the baseband adapter.
Could this be looked into? Thanks!
-Lucien