[59317] in Hotline Meeting

home help back first fref pref prev next nref lref last post

M38-370-4 GX110 Video Prob's

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Fri Apr 26 17:09:11 2002

Message-Id: <200204262109.RAA03542@killer.mit.edu>
To: hotline@MIT.EDU
Date: Fri, 26 Apr 2002 17:09:06 -0400
From: "Louis A. Isgur" <larugsi@MIT.EDU>

The above was reported with horizontal distortion on the monitor. The failure
was troubleshooted down to bad video bd, which has been replaced. Now all set.

SysName: M38-370-4 (GX110)
S/N    : 43DF20B
                              --Lou