[5842] in Hotline Meeting

home help back first fref pref prev next nref lref last post

M38-250A-1 (PVAX)

daemon@ATHENA.MIT.EDU (larugsi@ATHENA.MIT.EDU)
Tue Aug 13 19:53:59 1991

From: larugsi@ATHENA.MIT.EDU
To: hotline@ATHENA.MIT.EDU
Cc: cc@ATHENA.MIT.EDU, rita@ATHENA.MIT.EDU, net-help@ATHENA.MIT.EDU
Date: Tue, 13 Aug 91 19:53:45 EDT

Carson Chow has reported that his PVAX keeps receiving the 'No Hesiod Info'
message from time to time. This hangs his workstation up. Upon investigation,
I have found that the 10Base-T Transceiver with Lanview is bad. Carson was in a
bind, because he needed this workstation. So, the following is what I have 
done:
                    Seeing that the print server is down in the adjacent
                    38-246 room, I have swapped the 10Base-T transceivers.
                    The original transceiver, which resided in 38-250 has the
                    S/N of AA191070215. This, again is the bad transceiver,
                    which I have moved to 38-246. This is sitting on top of the
                    LNO3 with a note taped on it.
                    The good transceiver, which resided in 38-246 has the S/N
                    of AA191070253. This transceiver is now in 38-250 hooked
                    up to Carson's PVAX which is allowing him to carry on with
                    his work. As a rule, I generaly do not switch hardware
                    around. In this particular situation, I felt it was
                    necessary.
                    In conclusion, a new transceiver is needed A.S.A.P. to
                    replace the bad one in 38-246.
                                                 Thanks Much,
                                                            --Lou

home help back first fref pref prev next nref lref last post