| home | help | back | first | fref | pref | prev | next | nref | lref | last | post |
From: boojum@MIT.EDU Date: Fri, 17 Aug 2001 14:27:42 -0400 (EDT) Message-Id: <200108171827.OAA07083@geskekelud.mit.edu> To: hotline@MIT.EDU -------- The following came in to OLC. -Laura ---------------------------------------------------------------------- Dear Online help, This message is to the athena "ndelab" machine located in room 3-365. When I reboot, the display cycles through this message: WARNING:/iommu@0,10000000/sbus@0,10001000/espdma@5,8400000/esp@5,880000/sd@3,0 (sd3): Error for Command: read Error Level: Retryable Requested Block: 1694512 Error Block: 1694512 Vendor: CONNER Serial Number: 9JLA Sense Key: Media Error ASC: 0x11 (<vendor unique code 0x11>), ASQ: 0x43 The same numbers a cycled through every four times, on the fifth "Error Level: Retryable" becomes "Error Level: Fatal" and the numbers are incremented, and the cycle repeats. Can you help me. Sincerely, Anton Thomas Research Assistant Composite Materials & Nondestructive Evaluation Laboratory Room 3-365 77 Massachusetts Ave Cambridge, MA 02139
| home | help | back | first | fref | pref | prev | next | nref | lref | last | post |