[4841] in Hotline Meeting
W20-EAST-4 LOUD fan??
daemon@ATHENA.MIT.EDU (jjmorey@ATHENA.MIT.EDU)
Tue Apr 30 22:03:48 1991
From: jjmorey@ATHENA.MIT.EDU
To: hotline@ATHENA.MIT.EDU
Cc: rita@ATHENA.MIT.EDU, cc@ATHENA.MIT.EDU
Date: Tue, 30 Apr 91 20:26:51 EDT
this printer was found making noises which sound like there coming from the
fan. This has had some work just recently.
S/N RI 2192
S/N AB 72601 VT 4
Log# B 4A657
--jjmorey
Fri, 26 Apr 91
New development drawer by Ralph L. (DEC)
11:38 am Apr 19, 1991
massive paper jam.
theres a burnt smell and the gears dont seem to be catching.
Log# B 46775
John Ryfa (DEC) could not find any problems with this printer.
He stated that it was smelling because the fan unit was blocked up by
a box.
11:15 am Apr 17, 1991
poor print quality
Ralph L. has replaced the OPC, but also has the fusing unit and development
draw on parts hold.
Ralph L. (DEC) has replaced the fusing unit and cleaned out the
development drawer.
LOG#: B45529
Thu, 07 Mar 91 08:39:36
"man a" main motor error
Ralph L. (DEC) cleaned and adjusted the switch behind the development unit
and he also restarted the fan unit (which stopped.)