[4795] in Hotline Meeting

home help back first fref pref prev next nref lref last post

LNO3 (W20-EAST-4)

daemon@ATHENA.MIT.EDU (larugsi@ATHENA.MIT.EDU)
Fri Apr 26 19:14:25 1991

From: larugsi@ATHENA.MIT.EDU
To: hotline@ATHENA.MIT.EDU
Cc: cc@ATHENA.MIT.EDU, rita@ATHENA.MIT.EDU, jjdoher@ATHENA.MIT.EDU,
Date: Fri, 26 Apr 91 19:13:39 EDT

This printer was found with bad print quality. Several dark vertical lines
running down the output, with several blank lines present.
I have cleaned all internal parts with compressed air etc..
The Toner Roller was badly corrupted. I have cleaned/cleared this problem.
The printer is now displaying a ghostly shaded background which usualy points
to the developement drawer.
According to the resolved notes, W20-EAST-4 was worked on by Ralph L. (DEC)
on 4/16/91. Ralph had a fusing unit, and developemnt drawer on parts hold.
He had REPLACED the fusing unit, and had CLEANED the developement drawer.
I have placed a service call on this printer for Monday.
S/N  RI 2192  LOG # B49702.  The print queue has been shut down.
                                                               --Lou
P.S.
    For some reason, it has been approx. 20,000 pages since the last recorded
    maint.kit had been installed. I have replaced the maint.kit, and have 
    replaced the 3/4 full Toner Collection Bottle.
                                                              --Lou

home help back first fref pref prev next nref lref last post