[47412] in Hotline Meeting
case 141264
daemon@ATHENA.MIT.EDU (Barry M Stoelzel)
Thu May 6 11:44:07 1999
Message-Id: <199905061544.LAA27550@tyr>
To: hotline@MIT.EDU
Cc: barrys@MIT.EDU
Mime-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Date: Thu, 06 May 1999 11:44:04 EDT
From: Barry M Stoelzel <barrys@MIT.EDU>
MIT Polaris
84 Mass Ave 257 Cederhill St
Mail Stop W20-021 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 501-0045 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 5.6.99
------------
DHL# 8890241802
---------------------
RMA# 452
---------------------
******************************************************************
Part Description: 150 watt power-supply
------------------------------------------------
Part Number: 300-1279
------------------------------
Hotline Number: 141264
---------------------------
Building and Room#: W20-575
-----------------------
Machine Type: Sun Sparc V
-----------------------------
CPU S/N: 725c0672
----------------------------------
Hostname: W20-575-36
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Power-supply hot and noisey
------------------------------------------------------
Diags Used: removed pwrsupply, cleared it of all dust and re-
------------------------------------------------------
connected. No change.
------------------------------------------------------
Resolution: Replaced pwrsupply. system up and ok
------------------------------------------------------
Repaired By: barrys
------------------
Date: 5.6.99
------------