[47310] in Hotline Meeting
LOG # 140301 Rep.Form W20-575-74
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon Apr 26 17:35:07 1999
Message-Id: <199904262135.RAA09453@killer>
To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU
Date: Mon, 26 Apr 1999 17:35:02 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
84 Mass. Ave 257 Cederhill St
Mail Stop W20-021 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 4/27/99
------------
DHL# 8846762853
---------------------
RMA# 377924
---------------------
******************************************************************
Part Description: Hard drive for a Sparc4
------------------------------------------------
Part Number: 370-1753-03
------------------------------
Case Number:
---------------------------
Building and Room#: W20-575
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 621F010F
----------------------------------
Hostname: W20-575-74
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Intermittent scsi errors.
------------------------------------------------------
Diags Used: Re-installed software. No change.
------------------------------------------------------
------------------------------------------------------
Resolution: Replaced the drive & re-installed. Now o.k.
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 4/26/99
------------