LOG # 125108 REp.Form M38-370-14 (SS4)

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Fri Oct 30 18:42:12 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Fri, 30 Oct 1998 18:41:42 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
84 Massachusetts Ave                    257 Cedar Hill Street
Mail Stop W20-021                       Marlboro,Ma -1752
Cambridge Ma. 02139                     1 800 626 1661
(617) 253-1410                          1 508 460 1800
                                       
                                       
                                       
                                       

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   11/2/98
              ------------
DHL#   7684361370
     ---------------------
RMA#   352706
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   32 meg simm for a Sparc4
                  ------------------------------------------------
Part Number:   501-2471
             ------------------------------
Hotline Number:   125108
                ---------------------------
Building and Room#:   38-370
                    -----------------------
Machine Type:   Sparc4 110mhz
              -----------------------------
CPU S/N:   628F0AC4
         ----------------------------------
Hostname:   M38-370-14
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     Black crt (no video) crt power light & cpu light present.
            ------------------------------------------------------
Diags Used:   checked power cables/power cycled system etc... No change.
            ------------------------------------------------------
              Noticed that the 150 watt power supply was 3/4's covered with
            ------------------------------------------------------
Resolution:   dust. In my opinion, sufficient cooling was not able to take
            ------------------------------------------------------
Comments:     place, thus burning up the simm. Have replaced the simm under
            ------------------------------------------------------
              Polaris sell maint. Now back up and operating properly.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  10/30/98
      ------------