[45449] in Hotline Meeting
urania: Workstation-Watch Daily Gazette ops edition
daemon@ATHENA.MIT.EDU (Jonathon Weiss)
Mon Oct 19 22:55:03 1998
From: Jonathon Weiss <jweiss@MIT.EDU>
To: hotline@MIT.EDU
Cc: sipb-staff@MIT.EDU
Date: Mon, 19 Oct 1998 22:54:43 EDT
****** From wslogger:/usr/adm/messages.0 and syserr/syserr.remotes.0 ******
Sun Oct 18 06:45:00 through Mon Oct 19 06:45:00 1998
oliver:
-> 3009 soft error on unix: ALERT: Soft ECC Error in back side of DIMM Slot
-> 3005 soft error on unix: MEMORY Error/Addr 0x940000<SOFT ECC ERROR ON READ
14 unix: ft ECC Error in back side of DIMM Slot #, data bit #
8 afs: setting clock
4 unix: ERROR ON READ during CPU ACCESS>: 0x373f080
3 unix: afs: failed to store file (__)
1 unix: ot #, data bit #
When these logs are not truncated, they say:
Oct 19 15:40:25 OLIVER.MIT.EDU unix: MEMORY Error/Addr 0x940000<SOFT ECC ERROR ON READ during CPU ACCESS>: 0x373f080
Oct 19 15:40:25 OLIVER.MIT.EDU unix: ALERT: Soft ECC Error in back side of DIMM Slot 1, data bit 116
Oliver appears to still be usable, but solving the problem seems like
a good idea anyhow.
Jonathon