[45070] in Hotline Meeting
LOG # 121585 Rep.Form M2-225-3
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Wed Sep 23 19:06:59 1998
To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU
Date: Wed, 23 Sep 1998 19:06:42 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
84 Massachusetts Ave 257 Cedar Hill Street
Mail Stop W20-021 Marlboro,Ma -1752
Cambridge Ma. 02139 1 800 626 1661
(617) 253-1410 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 9/24/98
------------
DHL# 7684361484
---------------------
RMA# 347142
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: Floptical drive for an sgi indy R5000
------------------------------------------------
Part Number: 9490811
------------------------------
Hotline Number: 121585
---------------------------
Building and Room#: 2-225
-----------------------
Machine Type: sgi indy R5000
-----------------------------
CPU S/N: 0800690AE416
----------------------------------
Hostname: M2-225-3
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Floptical drive did not recognize the media being present
------------------------------------------------------
Diags Used: in the drive.
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the floptical drive.
------------------------------------------------------
Comments: now works
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 9/23/98
------------