This SS4 was reported down with error msgs displayed on the crt. Have verified
the errors as physical address errors, and have replaced the 50 watt pwr supply
with the 150 watt and the bad 32 meg simm as well.
SysName: M12-182-17 (Sparc4)
S/N : 630F007C
RMA # :
--Lou 6/8/98