[4278] in Hotline Meeting

home help back first fref pref prev next nref lref last post

Ethernet problems on portnoy and oliver

daemon@ATHENA.MIT.EDU (mhpower@ATHENA.MIT.EDU)
Thu Mar 28 17:06:13 1991

From: mhpower@ATHENA.MIT.EDU
To: hotline@ATHENA.MIT.EDU
Cc: sipb-staff@ATHENA.MIT.EDU
Date: Thu, 28 Mar 91 17:04:38 EST

Portnoy and oliver are having trouble with their Ethernet connections.
The console window on portnoy contains many messages of the form "un0:
N intermittent ethernet failures", where N is an number between 1 and
50. On both portnoy and oliver, there are problems in using "ping" to
connect to other systems (even ones on the same Ethernet cable), and
in contacting remote file servers.

Portnoy and oliver have adjacent taps at the far end of a single
Ethernet cable. However, there are other machines less far down on the
same Ethernet cable with no problems in network connectivity.

Portnoy and oliver are located in the SIPB office (W20-557). They are
the two workstations nearest the door.

Portnoy: IBM RT PC
         S/N: 26-0003697

Oliver: VAXstation II/RC
        S/N: WF62708035


Matt

home help back first fref pref prev next nref lref last post