REPAIR FORM M12-182-2 (Part 2)

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Thu Jan 29 22:32:32 1998

To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU
Date: Thu, 29 Jan 1998 22:32:23 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                    Silicon Graphics Inc.
1 Amherst St                           981  Almanor Ave
Mail Stop E40-362                      Sunnyvale   CA.  94086-0000
Cambridge, Ma 02139                     
(617) 253-1410 
                                       (TO PLACE HARDWARE SERVICE CALLS)
                                 
                                        *****   1-800-800-4744   *****
 
                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   
              ------------
FedEx #  
          ---------------------
Case ID # This form being used for E.M. Associates Rico)
          ---------------------
 
******************************************************************
Part Description:   eight (8 meg memory simms) for an sgi indy 46xz
                  ------------------------------------------------
Part Number:   Kingston 64 meg (8 simm kit)
             ------------------------------
Hotline Number:   1245
                ---------------------------
Building and Room#:   12-182
                    -----------------------
Machine Type:   sgi indy 46xz
              -----------------------------
CPU S/N:   08006909207D
         ----------------------------------
Hostname:   M12-182-2
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     Ecc cache parrity errors. Suspect a bad simm.
            ------------------------------------------------------
Diags Used:   Current procedure for this is to replace all simms.
            ------------------------------------------------------
              
            ------------------------------------------------------
Resolution:   Simms replaced, & system is up and in use.
            ------------------------------------------------------
Comments:     Somebody was cute and set a special root passwd. In order to 
            ------------------------------------------------------
              re-install software, the jumper on the sys bd has to be removed.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------