REPAIR FORM M38-370-13 SS4 Freeze Caper:

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Wed Jan 28 18:04:55 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Wed, 28 Jan 1998 18:04:49 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
1 Amherst St                            257 Cederhill St
Mail Stop E40-334                       Marlboro, Ma 01752
Cambridge, Ma 02139                     1 800 626 1661
Customer Number = 100116                1 508 460 1800

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   1/29/98
              ------------
DHL#   8500543203
     ---------------------
RMA#   312798
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   150 watt pwr supply & a 32 mmeg simm for a Sparc4
                  ------------------------------------------------
Part Number:   300-1279-02 & 501-2471
             ------------------------------
Hotline Number:   1258
                ---------------------------
Building and Room#:   38-370
                    -----------------------
Machine Type:   Sparc4
              -----------------------------
CPU S/N:   629F0717
         ----------------------------------
Hostname:   M38-370-13
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     System hangs/feezes/physical address memory errors -- under
            ------------------------------------------------------
Diags Used:   Solaris 2.5.1 with Athena 8.1. Have replaced the 32 meg simm
            ------------------------------------------------------
              as well as replacing the 50 watt pwr supply with the 150 watt
            ------------------------------------------------------
Resolution:   one. System now back up and in use.
            ------------------------------------------------------
Comments:     
            ------------------------------------------------------
              
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  1/28/98
      ------------