[41138] in Hotline Meeting
repair form
daemon@ATHENA.MIT.EDU (**********************)
Thu Dec 11 12:01:36 1997
To: hotline@MIT.EDU
Cc: cpontier@MIT.EDU
Date: Thu, 11 Dec 1997 12:01:31 EST
From: ********************** <cpontier@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 12-11-97
------------
DHL# 7537143014
---------------------
RMA# 306004
---------------------
******************************************************************
Part Description: SGI 5000 System board
------------------------------------------------
Part Number: 03-8123-016
------------------------------
Hotline Number: C125
---------------------------
Building and Room#: 3-462
-----------------------
Machine Type: SGI 5000
-----------------------------
CPU S/N: 0800690AE380
----------------------------------
Hostname: sodor
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: System wouldn't boot up.
------------------------------------------------------
Diags Used: Replaced system board.
------------------------------------------------------
------------------------------------------------------
Resolution: Fixed
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: Chris
------------------
Date: 12-11-97
------------