[40608] in Hotline Meeting
REPAIR FORM M12-182-14 SS4 Freeze Caper:
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon Nov 10 17:32:16 1997
To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Mon, 10 Nov 1997 17:32:12 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped:
------------
DHL# using the Polaris form for Sun/time/materials.
---------------------
RMA# Sun Rma # 818554 or service order # 3133894
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: power supply for a sparc4 (150 watt)
------------------------------------------------
Part Number: 300-1279-02
------------------------------
Hotline Number: B112
---------------------------
Building and Room#: 12-182
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 629F0725
----------------------------------
Hostname: M12-182-24
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: SS4 hangs under Solais 2.5.1. Sun engineering has an FCO for
------------------------------------------------------
Diags Used: this symptom. It is to change the 300-1257-02 50 watt power
------------------------------------------------------
supply to a 300-1279-02 150 watt power supply.
------------------------------------------------------
Resolution: Have done so on the above system. The systemm bd -02 REV50 was
------------------------------------------------------
Comments: not changed. System back up and running.
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 11/10/97
------------