[37524] in Hotline Meeting
REPAIR FORM M11-113-14
daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Fri Mar 21 19:35:41 1997
From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Cc: larugsi@MIT.EDU, jjmorey@MIT.EDU
Date: Fri, 21 Mar 1997 19:35:37 EST
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 3/24/97
------------
DHL# 8210244641
---------------------
RMA# 270177
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: new style floppy drive for a Sparc4
------------------------------------------------
Part Number: 501-2854-01
------------------------------
Hotline Number: 3361
---------------------------
Building and Room#: 11-113
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 630F0204
----------------------------------
Hostname: M11-113-14
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Unable to retrieve floppy from drive.
------------------------------------------------------
Diags Used: Drive appears to be mis-aligned internaly.
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the floppy drive under sun self maint.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 3/21/97
------------