[36996] in Hotline Meeting
REPAIR FORM M4-370-1
daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Wed Feb 19 19:09:09 1997
From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Cc: jjmorey@MIT.EDU, larugsi@MIT.EDU
Date: Wed, 19 Feb 1997 19:09:05 EST
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 2/20/97
------------
DHL# 8210244265
---------------------
RMA# 266095
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: 17 inch color sun monitor
------------------------------------------------
Part Number: 365-1316
------------------------------
Hotline Number: 2180
---------------------------
Building and Room#: 4-370
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 638F0B88
----------------------------------
Hostname: M4-370-1
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Monitor displaying gree/yellowish tint.
------------------------------------------------------
Diags Used: Checked all connection. Tried another monitor.
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the monitor under sun self maint.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 2/19/97
------------