[36757] in Hotline Meeting

home help back first fref pref prev next nref lref last post

Re: Fiber Jam'd w20-575

daemon@ATHENA.MIT.EDU (ndpope@MIT.EDU)
Wed Feb 5 08:47:03 1997

From: ndpope@MIT.EDU
To: hotline@MIT.EDU, pcservice@MIT.EDU
In-Reply-To: Your message of "Tue, 04 Feb 1997 08:37:48 EST."
             <199702041337.NAA19006@test-sgi.MIT.EDU> 
Date: Wed, 05 Feb 1997 08:47:01 EST


Hey guys,
	Fiber's problem was the paper guide right behind the fuser.  It was
seated in the wrong position.  I've seen it before and I'm sure I'll
see it again.  Put it where it should be and printed out 30 pages worth
of test prints. Couldn't even print one before.

Machine name: Fiber - HP 4si
Machine loaction: W20-575
Serial number: USBB114882
MIT Tag numnber: MIT-0265605
Parts used: none

Log number: R9693
Status: CLOSED

				Kyle Pope