Case # R8209
Machine: M4-035-17
Location: 4-035
Problem: No power

	Replaced power supply.  E-mailed to replace software as crash from
power going out presumably damaged system.  Checked back again Friday, up and
running.  

Machine S/N: 080069095EFB
Parts used: 9430813
Closed 8/26/96