Listed below are shutdowns for your information.  If you have any
question, please feel free to contact me.  Andrea

Building:       38
System:         Supply Fan 2B and 3A
Date:           3/10 & 3/11/96
Day:            Sunday and Monday
Time:           11:00 PM (Sun.) - 7:00 AM (Mon.)
Duration:       8 Hours
Reason:         Preventive maintenance work
Effect:         PM# 701947-SF2B srvices ventilationn/heat/cooling for
                floors 1-6N; PM#701939 --SF3A services ventilation/heat/cooling
                for
                floors 1-6S; PM#701941 - SF1 services Basement ventilation.

Building:       11
System:         Air Handler 2 and Roof Fan 2
Date:           3/8/96
Day:            Friday
Time:           5:00 AM- 7:00 AM
Duration:       2 hours
Reason:         Preventive maintenance work
Effect:         PM# 703607 and 703606 services 3rd floor
                ventilation/heat and cooling.

Building:       E17-133
System:         Fume exhaust hood fan (PM#700359 - Penthouse)
Date:           March 19, 1996
Day:            Tuesday
Time:           7:30 AM - 3:00 PM
Duration:       7.5 hours
Reason:         Fume exhaust hood control modification. Exhaust valve
                damper to replace V. F. D.
Effect:         Loss of hood.

Building:       E25
System:         Fan Hood Exhausts -time down up to 1 hour each.
Date:           3/11-12/96
Day:            Monday and Tuesday
Time:           11:00 PM (Mon.) - 7:00 AM (Tues.)
Duration:       8 Hours
Reason:         Preventive Maintance Work
Effect:         PM#707853 services Rm. 649, #707851 serv. 344, #707849
                serv. 548, #707847 serv. 445, #707846 serv. 345, #707854
                serv. 550, #707855 serv. 345, #707856 serv. 250A&B, #707817
                serv. 325, #707816 serv. 230, #707810 serv. 325, 707809 serv.
                627, 707808 serv. 621W, 707807 serv. 326,707805 serv. 421,
                707804 serv. 621E.

Building:       E25
System:         Fan Exhaust Hoods - time down up to 1 hour each
Date:           3/12 - 13/96
Day:            Tuesday and Wednesday
Time:           11:00 PM (Tues.) - 7:00 AM (Wed.)
Duration:       8 Hours
Reason:         Preventive Maintenance Work
Effect:         PM#707827 serv. Rm. 533, #707826 svc. 537, #707825
                serv. 633, #707824 serv. 529, #707821 serv. 446B, #707820 serv.
                626,#707819 serv. 429, #707818 serv. 629, 707836 serv. 530, 707
                835 serv. 642 A,B & C, 707834 serv. 637, 707833 serv. 028, 7078
                32 serv. 438, 707831 serv. 633W, 707830 serv. 032, and 707828
                serv. 534.

Building:       1 (Basement- d'arbeloff Lab area)
System:         Domestic hot water--entire building all sinks
Date:           3/7/96
Day:            Thursday
Time:           7:00 AM - 3:00 PM
Duration:       8 Hours
Reason:         Renovations/demolition/removal--cut and cap water
                lines.
Effect:         Loss of hot water in entire building--all sinks only.

Building:       68
System:         Air Handlers, Exhaust Fans
Date:           3/11/96
Day:            Monday
Time:           3:00 PM - 11:00 PM
Duration:       8 Hours
Reason:         Preventive Maintenance Work
Effect:         AH4 services AQ - all exhaust fans service AQ hoods:
                Back-up from AH1, 2 & 3 will supply heating, ventilation & air
                conditioning (HVAC) air while AH4 is off.

Building:       68-284 (Hot Lab)
System:         Exhaust Hood #716566.
Date:           3/12/96
Day:            Tuesday
Time:           7:30 AM - 11:30 AM
Duration:       4 hours
Reason:         Bearings on fan starting to fail (need to be changed).
Effect:         Loss of exhaust-laboratory air.