[31628] in Hotline Meeting

home help back first fref pref prev next nref lref last post

SGI repairs.

daemon@ATHENA.MIT.EDU (Scott Dunham)
Tue Jan 16 13:38:55 1996

Date: Tue, 16 Jan 96 13:39:28
From: sad@MIT.EDU (Scott Dunham)
To: Hotline@MIT.EDU
Cc: dcns-cLuster@MIT.EDU

Date:1/16/95
Problem reported:Blank display.
Serial number and location of CPU: 66-080-13,0800690896ca.
Action taken: replaced X-Z video board assembly and ran diags. Passed all diags 
with flying colors.
Parts used:030-8235-002,030-8234-002.
PC Service log number:R6343.
Notes:none.


Date:1/16/95
Problem reported:Dead.
Serial number and location of CPU:7-100,080069092458.
Action taken:Replaced dead power supply. Ran diags, passed all tests.
Parts used:9430813.
PC Service log number:Serial number was not found in our database??


I will be coming over this afternoon to reassemble Thesis-1 and 2 and get them 
out of Lou's little piece of paradise.

Cheers,
scott