[31230] in Hotline Meeting
REAPAIR FORM STAGE5 SPARC5
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Fri Dec 8 20:44:42 1995
To: hotline@MIT.EDU
Cc: joewelch@MIT.EDU
Date: Fri, 08 Dec 1995 20:44:37 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 12/11/95
------------
DHL#
---------------------
RMA#
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: Scsi cable for a Sparc5 floppy drive
------------------------------------------------
Part Number:
------------------------------
Hotline Number: C127
---------------------------
Building and Room#: E40-014B
-----------------------
Machine Type: Sun Sparc5
-----------------------------
CPU S/N: 537F14B5
----------------------------------
Hostname: Stage5
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Floppy drive would not eject floppy's
------------------------------------------------------
Diags Used: Tried system bd, then scsi cable.
------------------------------------------------------
------------------------------------------------------
Resolution: Replaced scsi cable
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 12/8/95
------------