Date Received:
------------
******************************************************************
Part Description: Triax Color Cable
-----------------------------------------------
Part Number: 17-02906-02
---------------------------
Hotline Number: 7188
-------------
Building and Room#: E51-007
----------------------
Machine Type: DS5000/25
----------------------------
CPU S/N: AB22409YUJ
------------------------
Hostname: E51-007-1
-----------------------
******************************************************************
Repair Information:
------------------
Symptoms: Colors flickering, and constant color changes
-----------------------------------------------------
Diags Used: Located the cause of problem by gently moving the color cable.
-----------------------------------------------------
-----------------------------------------------------
Resolution: Have replaced the triax color cable under CSA.
-----------------------------------------------------
Comments:
----------------------------------------------------
----------------------------------------------------
Repaired By: L.A.I.
-------------------------
Date: 7/21/95
------------