[22204] in Hotline Meeting

home help back first fref pref prev next nref lref last post

Re:problem with EMCH

daemon@ATHENA.MIT.EDU (sharari@tcm.mit.edu)
Tue Apr 12 16:40:09 1994

To: hoffmann@MIT.EDU
Cc: trans-trb@MIT.EDU, net-info@MIT.EDU, hotline@MIT.EDU, network@MIT.EDU
Date: Tue, 12 Apr 94 16:39:24 -0400
From: sharari@tcm.mit.edu

Hi Ron,
MRXI repeater ( EMCH) and ST-500 Transceiver are bad.
Replaced the St-500 and the MRXI with ASANTE AH1012.
All working fine now.

Mohamad.
------- Forwarded Message

Return-Path: hoffmann@MIT.EDU
Received: from PADDINGTON.MIT.EDU by MIT.EDU with SMTP
	id AA28214; Tue, 12 Apr 94 11:25:29 EDT
From: hoffmann@MIT.EDU
Received: by Paddington (5.57/4.7) id AA22140; Tue, 12 Apr 94 11:25:27 -0400
Date: Tue, 12 Apr 94 11:25:27 -0400
Message-Id: <9404121525.AA22140@Paddington>
To: trans-trb@MIT.EDU
Cc: net-info@MIT.EDU, hotline@MIT.EDU, network@MIT.EDU
Subject: problem with EMCH

1. High priority:

Repeater EMCH is behaving flakey AND machines served by it
are experiencing packet loss.

Can you look into this?

2. Lower priority:

Also, in troubleshooting this problem I noticed that second
floor drops in 35 are being served by EMCH through a tie
cable when there is a repeater on the second floor with none
of it's UTPE ports in use.  It would be good to move the
second floor drops to the second floor repeater (EW20).

- -Ron

Ref: Workstation M35-212-1.MIT.EDU is experiencing packet loss.

------- End of Forwarded Message