[19443] in Hotline Meeting
guilder E40-173 needs DEC Service
daemon@ATHENA.MIT.EDU (rita@MIT.EDU)
Tue Nov 2 11:03:16 1993
From: rita@MIT.EDU
To: hotline@MIT.EDU
Cc: sbuckley@MIT.EDU
Date: Tue, 02 Nov 93 11:02:50 EST
Machine: guilder
Type: DEC DS3100
Serial Number: AB90703SHB
Location: E40-173
Contact: Stephen Buckley, 3-6610
Problem: The monitor has dotted rastor lines going down it.
I've power cycled the CPU and monitor and reseated the power
cords, keyboard and mouse cables to have no effect on the system.
I do not hear the disk spinning up when I power cycle
this machine.
It's toasted and needs your attention.
Please check on it.
- sounds like and looks like a power supply problem or
a hard disk problem to me
- the disk has "stuff" on it so please contact Stephen Buckley
before replacing or reformatting stuff
-Rita HelpDesk (and Rita Hotline for this service call)